INVT MODEL GD20 – 380V Three Phase

From: R4,784.00

Goodrive20 series inverters feature excellent drive and control performance for using of sensorless vector control technology, and improve usability and reliability for the enriched hardware configurations and software functions, meeting different industrial applications. Goodrive20 series 18.5KW~110KW comes standard with built-in DC reactor, 18.5~37KW built-in standard brake unit, 45~110KW optional built-in brake unit, full range of independent air duct design, which improves product reliability and performance, and enhances product competitiveness.

SKU: N/A Categories: ,

Description

Excellent Control Performance

Adopting PG-free vector control mode, excellent control performance
Excellent vector control performance

Optimized Structure Design

Optimized spare utilization, models (≥18.5kW) is much smaller than existing inverters
Mini design for inverters (≤ 2.2kW), abreast installation of multiple inverters, reducing installation space

Multi-function and easy to use

DC reactors are built-in inverters ≥18.5kW

Diverse Application Requirements

Simple PLC, multi-speed control, built-in PID, torque control, multi-point V/F curve, multiple braking methods, instantaneous power failure without stopping, etc.

Applications

Vector control platform products, powerful, excellent performance, can be widely used in small and medium power applications, such as food machinery, plastic machinery, ceramic equipment, petroleum machinery, cable machinery, air compressors, machine tools, woodworking machinery, textile machinery, printing and packaging equipment, chemical equipment, environmental protection equipment, transportation equipment, etc.

Specifications

Function Specification
Power input Input voltage (V) AC 1PH 220V (-15%)~240V(+10%) AC 3PH 220V (-15%)~240V(+10%)
AC 3PH 380V (-15%)~440V(+10%)
Input current (A) Refer to the rated value
Input frequency (Hz) 50Hz or 60Hz Allowed range: 47~63Hz
Power output Output voltage (V) 0~input voltage
Output current (A) Refer to the rated value
Output power (kW) Refer to the rated value
Output frequency (Hz) 0~400Hz
Technical control
feature
Control mode SVPWM, SVC
Motor Asynchronous motor
Adjustable-speed ratio Asynchronous motor 1:100 (SVC)
  Speed control accuracy ±0.2% (SVC)
Speed fluctuation ± 0.3% ( SVC)
Torque response <20ms (SVC)
Torque control accuracy 0,1
Starting torque 0. 5Hz/150% ( SVC)
Overload capability 150% of rated current: 1 minute
180% of rated current: 10 seconds
200% of rated current: 1 second
Running control feature Frequency setting method Digital setting, analog setting, pulse frequency setting, multi-step speed running setting, simple PLC setting, PID setting, MODBUS communication setting
Shift between the set combination and set channel.
Auto-adjustment of the
voltage
Keep a stable voltage automatically when the grid voltage
transients
Fault protection Provide comprehensive fault protection functions:
overcurrent, overvoltage, undervoltage, overheating, phase loss and overload, etc.
Start after speed tracking Smoothing starting for running motor
Peripheral interface Analog input 1 (AI2) 0~10V/0~20mA and 1 (AI3) -10~10V
Analog output 2 (AO1, AO2) 0~10V/0~20mA
Digital input 4 common inputs, the Max. frequency: 1kHz;
1 high speed input, the Max. frequency: 50kHz
Digital output 1 Y1 terminal output
Relay output 2 programmable relay outputs
RO1A NO, RO1B NC, RO1C common terminal
RO2A NO, RO2B NC, RO2C common terminal Contact capacity: 3A/AC250V
Others Temperature of the running environment -10~50°C, derate 1% for every additional 1℃ when above 40℃
DC reactor Standard embedded DC reactor for the inverters ( ≥
18.5kW)
Installation mode Wall and rail installation of the inverters(single phase 220V/three phase 380V, ≤2.2KW and three phase 220V,
≤0.75KW)
Wall and flange installation of the inverters(three phase 380V, ≥4KW and three phase 220V, ≥1.5KW)
Braking unit Standard for the inverters≤37kW and optional for the inverters of 45~110kW
  Protective degree IP20
Note: The inverter with plastic casing should be installed
in metal distribution cabinet, which conforms to IP20 and of which the top conforms to IP3X.
Cooling Air-cooling
EMI filter Embedded C3 filters for the inverters(three phase 380V,
≥4kW and three phase 220V, ≥1.5kW) ; external C2 filter is optional for all series;
Optional filter: meet the degree requirement of
IEC61800-3 C2, IEC61800-3 C3
Safety Meet the requirement of CE

Downloads

Name Edition format format Size download
GD20 Catalog(EN)-201907(V1.0) V1 PDF 9.87MB
Goodrive200A Inverter Operation Manual_V2.3 V1.5 PDF 4.1MB
GD20 Series Technical Datasheet V2.3 PDF 222KB